Overview

Basic Info.

Model NO.
MG-CANSX
Condition
New
Customized
Customized
Material
Stainless Steel
Model No.
Mg-Canex
OEM
Yes
ODM
Yes
Brand
Odot
Applied New Energy
Solar/Photovoltaic-PV/Lithium Battery Industry
Applied Machinery Industry
CNC/Food and Beverage/Grain and Oil Machinery/Smar
Other Industry
Railway/ Urban Rail/Building/ HVAC
Optional Io Modules
Current/Voltage Input Output PT100/Thermocouple En
Warranty
3 Years
Certificates
CE, ISO9001:2015
Applied Energy
Thermal Plant/Hydropower Station/Ptd
Delivery
1~2 Weeks
Transport Package
Cartons
Trademark
ODOT
Origin
Sichuan
HS Code
8517623990
Production Capacity
10000 Piece/ Month

Product Description

Product Description

MG-CANSX Protocol Converter

CANopen to Modbus TCP protocol converter

MG-CANSX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.
As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.

Product Parameters

The gateway comes with its own configuration software, and the parameter configuration information is downloaded to the gateway through the network port. The gateway automatically saves the latest configuration information. There is no need to load configuration after the gateway is powered off and on.
Gateway is the master of CANopen on CANopen network, and can connect to the equipment of CANopen slave
The gateway is Modbus Server on Modbus TCP network and supports up to 5 TCP clients access. Double Ethernet port, with switch function, support cascade.

2KV network port isolation protection, 10M/100Mbps rate adaptive, automatic MDI/MDIX reversal.
It supports address mapping mode, and realize the rapid response to TCP client request.
Modbus TCP supports function code: 0 x01, 0 x02, 0 x03, 0 x04, 0 x05, 0 x06, 0 x0F, 0 x10.
6KB large data buffer, more data transfer volume.
CAN interface supports CANopen working mode.
CAN interface Baud rate: 10K~1Mbps.
CANopen protocol conforms to DS301 V4.02 and supports NMT master, PDO, SDO and Heartbeat.
It supports one-key reset function to restore factory Settings.
35mm DIN-rail installation.
EMC meets EN 55022:2010 & EN55024:2010 international standards.
 

MG-CANSX Protocol Converter

CANopen to Modbus TCP protocol converter

MG-CANSX is a protocol converter from CANopen to Modbus TCP. The device plays as the master in the CANopen network and it could be connected to the standard CANopen slave devices. The data transmission supports PDO, SDO, and error control supports Heartbeat. It Supports synchronous and asynchronous message sending.
As a TCP server in Modbus TCP network, the device could be accessed by 5 TCP clients at the same time, and it could be connected to PLC controller and various kinds of configuration software. It could also connect optical transceiver and to realize long-distance data transmission.



Protocol Converter Modbus-RTU to Canopen Gateway
 

Certifications

Protocol Converter Modbus-RTU to Canopen Gateway

Company Profile

Protocol Converter Modbus-RTU to Canopen GatewayProtocol Converter Modbus-RTU to Canopen GatewayProtocol Converter Modbus-RTU to Canopen Gateway

Application

Protocol Converter Modbus-RTU to Canopen Gateway

FAQ

1.How could i get the manual, technical detail and software?
You can click the software & manual page to download the realted product details or contact us to get it.


2.Do you have after sale support?
Yes we provide all the realted technical support including remote support.
And We will provide you any necessary online training and support too.


3. What is the warranty?
All the ODOT products is with the warranty of 3 years.
Only ODOT-S7PPI/PPI V2.0 is with a warranty of 1 year.


4. How is the payment terms?
100% T/T in advance.


5. What is your shipping channel?
We support all the main stream courier company including: Fedex,  TNT, DHL, UPS, and Aramex.


6. What is your lead time?
We will arrange the delivery in 1~ 2 day if we have finished products in stock.
If we have no stock and the lead time will be 1~2 weeks.


7. Do you provide any customized services?
Yes, please contact us with your application details.
We accpet deep customized services including OEM, ODM and there will be a MOQ.


8. Do you accept cooperation as distributors?
Yes, partner and distributorship inquiry are warmly welcomed.