• Codesys PLC Odot C3351 Modbus Controller
  • Codesys PLC Odot C3351 Modbus Controller
  • Codesys PLC Odot C3351 Modbus Controller
  • Codesys PLC Odot C3351 Modbus Controller
  • Codesys PLC Odot C3351 Modbus Controller

Codesys PLC Odot C3351 Modbus Controller

Task: Program
Structure: Combination
Signal: Discrete
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: ISO: 9001, CE
Condition: New
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
C3351
Customized
Non-Customized
Material
ABS Plastic Shell
Protocol
Modbus-TCP/ Modbus-RTU
Expansion Module
Supports up to 32PCS
Programming Language
IEC 61131-3 (Ld, Il, St, CFC/Fbd, Sfc)
Programming Software
Codesys Sp17
Program Memory
1mbytes
Transport Package
Carton
Specification
115*51.5*75mm
Trademark
Odot
Origin
China
HS Code
8517623990
Production Capacity
5000 Piece/ Month

Product Description

Codesys PLC Odot C3351 Modbus Controller

 

System power supply 22-28VDC(Nominal 24VDC)
Protection Anti-reverse connection protection
Module consumption 70mA@24Vdc
Internal Bus supply current Max:2.0A@5VDC
Isolation system to site power isolation
Field power supply 22-28V(Nominal 24V)
Field supply current Max. DC 8A
Number of supported I/O modules 32 pcs
Wiring diameter Max.1.5mm² (AWG 16)
Way to install 35mm DIN rail
Dimension 115 * 65.5 * 75mm
Weight 120g

 

Codesys PLC Odot C3351 Modbus Controller

Programming Specification

Programming Specification
Programming Software CODESYS SP17
Programming language IEC 61131-3 (LD, IL, ST, CFC/FBD, SFC)
Maximum State Tasks 5
Bit Instruction Cycle 0.21us
Word Transfer Cycle 0.39us
Floating Point Operation Cycle 0.42us
Program Memory 1MBytes
Data Storage 1MBytes
Power-down Protection Area 3KBytes
RTC: Not Supported
Maximum Expansion Module 32
Modbus Master Max Channel Numbers 10
Modbus Master Command Max Length:
Function Code 1(Read Coils) 2000
Function Code 2(Read Discrete Inputs) 2000
Function Code 3(Read Holding Registers) 125
Function Code 4(Read Input Registers): 125
Function Code 15(Write Multiple Coils) 440
Function Code 16(Write Multiple Registers) 27
Function Code 23(Read/Write Multiple Registers) 25+25
Interface Parameters
Interface 2 * RJ45 & 1 * RS485
Network Port Baud Rate 10/100Mbps, Adaptive and full duplex
Network Protocol Modbus TCP,the default IP of the device is 192.168.0.15
Serial Port Configuration(RS485) Supports Modbus RTU/ASCII, the baud rate is 2400~115200bps, and supports the parameter configuration of parity code and stop bit
 LED indicator  6 LEDs PWR STAT RUN NET IRN IER
Link Parameters
Modbus TCP Client Max supports for connecting 6 Modbus TCP servers
Modbus TCP Server Max supports for 6 Modbus TCP clients connected
Modbus RTU Master Max supports for connecting 5 slave devices
 Modbus RTU Slave  Max supports for connecting 1 master device



Codesys PLC Odot C3351 Modbus Controller
Codesys PLC Odot C3351 Modbus Controller
Codesys PLC Odot C3351 Modbus Controller
Codesys PLC Odot C3351 Modbus ControllerCodesys PLC Odot C3351 Modbus Controller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now