Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement, PLC
Certification: ISO: 9001, CE
Samples:
US$ 12.95/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Company Profile
  • Application
Overview

Basic Info.

Model NO.
CT-5801
Condition
New
Customized
Customized
Material
Stainless Steel
Size
115*14*75mm
Mounting Type
35mmdin-Rail
Weight
65g
Operational Temperature
-40~85ºC
Operational Humidity
5%~95% Rh(No Condensation)
Protection Level
IP 20
Model
CT-5801
Brand
Odot
Warranty
3 Years
Lead Time
1~2 Weeks
Aplication
for Odot Io System
Transport Package
Carton
Specification
115*14*75mm
Trademark
ODOT
Origin
Sichuan
HS Code
8517623990
Production Capacity
10000 Piece/ Month

Product Description

Product Description

ODOT CT-5801 Terminal module

Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)

Product Parameters

Module Type
State indicator
Internal Bus
Buckle
Grounding Resilient Sheet
Terminal Cover
 

CT-5801Terminal module (Required)


Module Description


The terminal module is used to stabilize internal bus communication and it is
required.The terminal module CT-5801 has no process data and no configuration
parameters.
CT-5801 requires no configuration and occupies no slot in configuration.

Detailed Photos

 

Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)

IO Modules Optional
CT-1228  (new) CT-1228:8 channels digital Intput/24VDC/sink type, PNP,supports counting
function(Max. counting frequency of 200Hz)
,the input voltage is 24VDC, the input high level is valid
CT-1218   CT-1218:8 channels digital Intput/24VDC/sink type, PNP,supports counting
function(Max. counting frequency of 200Hz)
,the input voltage is 24VDC, the input high level is valid
CT-121F CT-121F:16 channels digital Intput/24VDC/sink type, PNP,supports counting
function(Max. counting frequency of 200Hz)
,the input voltage is 24VDC, the input high level is valid
CT-222F CT-222F: 16 channels digital Output, source, PNP, 24Vdc/0.5A,the output voltage is 24VDC, the output high level is valid
CT-122F CT-122F: 16 channels digital input, source, NPN, 24VDC, supports counting
function(Max. counting frequency of 200Hz)
,the input voltage is 0V, the input low level is valid
CT-221F CT-221F:16 channels digital Output/24VDC/0.5A/sink type, NPN,the output voltage is 0V, the output low level is valid
CT-124H CT-124H: 32 channels digital input, sink or source, 34Pin male connector, 24Vdc,
 counting function supported (counting frequency up to 200Hz)
CT-222H CT-222H: 32 channels digital output, source, 24Vdc/0.5A,34Pin male connector
CT-2224 CT-2224   4-channel digital output ,Source type, 5.5-40VDC ,single channel Max output. 3.3a /4 channel with Max output. 2A per channel. Channels
can be used in parallel
CT-2228 CT-2228:8 channels Digital Output ,source,PNP,24Vdc/0.5A,
 the output voltage is 24V
DC, the output high level is valid
CT-2718 CT-2718:8 channels Relay Output ,( 9~30Vdc@2A,[email protected], [email protected])
CT-3168  CT-3168:8 channels Analog Input,0~5Vdc,-5~5Vdc,0~10Vdc,-10~10Vdc,15 bits/16 bits,Single-end
CT-3238 CT-3238:8 channels analog input/ 0& 4-20mA/15-bit,single ended
CT-3268 CT-3268:8 channels analog input/-20~20mA/15-bit,single ended
CT-3713 CT-3713:3 channels Analog Input,RTD(PT100)
CT-3723  CT-3723:3 channels Analog Input,RTD(PT1000) 
CT-3804 CT-3804:4 channels Analog Input,Thermocouple( J type, K type, E type, T type, Stype, R type, B type, N type, C type)
CT-3808 CT-3808:8 channels Analog Input,Thermocouple( J type, K type, E type, T type, Stype, R type, B type, N type, C type)
CT-4154 CT-4154:4 channels Voltage Output,0~5Vdc,-5~5Vdc,0~10Vdc,-10~10Vdc,16 bits,Single-end
CT-4158 CT-4158:8 channels Voltage Output,0~5Vdc,-5~5Vdc,0~10Vdc,-10~10Vdc,16 bits,Single-end
CT-4234 CT-4234:4 channels analog output, 0& 4-20mA/16-bit,single ended
CT-4238 (new) not available for sale  CT-4238:8 channels analog output, 0& 4-20mA/16-bit,single ended
CT-5102 CT-5102:  2 channels encoder/5V input/Quadrature decoding, direction pulse, high speed counting, 2channels DI, 2channels DO,
 2 channels encoder/5V input/Quadrature decoding, direction pulse, high speed counting, 2channels DI, 2channels DO, 2 way 5V output, 32bit, Max input frequency of 1.5MHz2 way 5V output, 32bit, Max input frequency of 1.5MHz
CT-5112 CT-5112: 2 channels encoder/24V input/Quadrature decoding, direction pulse, high speed counting, 2channels DI, 2channels DO,
 2 way 24V output, 32bit, Max input frequency of 1.5MHz.
CT-5122 CT-5122: 2-channel encoder/SSI input
CT-5142 CT-5142: 2-channel encoder/differential input/quadrature decoding, direction pulse,
 high-speed counting, 2-channel DI,
 2-channel DO, 32bit, maximum input frequency 10MHz
CT-5321 CT-5321:serial port communication sub-module (RS232, RS485,RS422, either serial port is
optional, it supports modbus-RTU /ASCII,master or slave mode, transparent transmission mode)
CT-5711 CT-5711:Fieldbus Extended Master Module( CT-5711 need work with CT-5721) 
CT-5721 CT-5721:Fieldbus Extended Slave Module  ( CT-5711 need work with CT-5721)
CT-5801  CT-5801:Terminal module as extra module, take no module channel, (  required for each network adapter)
CT-623F CT-623F:8 channels / digital input / 24VDC / source or sink type &8 channels / digital output / 24VDC / source  type, single output channel max current 500mA
CT-7220  CT-7220:Expansion power Supply( System power input 24Vdc,Output 5Vdc/2A,Field power input 24Vdc,Output 24Vdc/8A) take no module channel.
CT-7220Power Supply Extension Module  required as BOM included a 15 module rack,
aslo IO Config software noticed the decreasing "Total Residual Current",
MTE034 MTE034: Din Rail, 32 channels male connector,spring terminal connection
 ( accessories  for CT-124H and CT-222H )
DX210-3SFX-2000 Length 2 meters, flame retardant material, flexible wire, both ends are female connector 
( accessories  for CT-124H and CT-222H )


 

Certifications

Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)

Company Profile

Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)

Application

Remote Io Terminal Module as Extra Module for System Stable, Take No Module Channel, (Required for Every Network Adapter)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now